title: اجزای داخلی سرور HPE DL380 Gen10 Plus
description: "## توضیحات درایو باکس Drive BOX **سرور HPE DL380 Gen10 Plus** **باکس های جلویی سرور****DL380 Gen10 Plus 8SFF** ![](https://www.dana-corp.com/wp-content/uploads/2024/06/Front-boxes-SFF.png) | **شماره** | **توضیحات** |   | | --- | --- | --- | | 1 | Box 1 | |…"
url: "https://www.dana-corp.com/kb/hpe-dl380-gen10plus-guide/internal-components/"
updated: "2024-06-06"
category: راهنمای سرور HPE DL380 Gen10 Plus
---

# اجزای داخلی سرور HPE DL380 Gen10 Plus

## توضیحات درایو باکس Drive BOX **سرور HPE DL380 Gen10 Plus**

**باکس های جلویی سرور****DL380 Gen10 Plus 8SFF**

![](https://www.dana-corp.com/wp-content/uploads/2024/06/Front-boxes-SFF.png)

| **شماره** | **توضیحات** |   |
| --- | --- | --- |
| 1 | Box 1 |  |
| 2 | Box 2 |  |
| 3 | Box 3 |  |

![](https://www.dana-corp.com/wp-content/uploads/2024/06/Front-boxes-LFF.png)

| **شماره** | **توضیحات** |
| --- | --- |
| 1 | Box 1 |
| 2 | Box 2 |
| 3 | Box 3 |

**باکس های پشتی سرور****DL380 Gen10 Plus 8SFF**

![](https://www.dana-corp.com/wp-content/uploads/2024/06/Rear-boxes-SFF.png)

| **شماره** | **توضیحات** |
| --- | --- |
| 1 | Box 4 |
| 2 | Box 5 |
| 3 | Box 6 |

![](https://www.dana-corp.com/wp-content/uploads/2024/06/Rear-boxes-LFF.png)

| **شماره** | **توضیحات** |
| --- | --- |
| 1 | Box 4 |
| 2 | Box 5 |

**باکس های داخلی (****Midplane LFF****) سرور****DL380 Gen10 Plus 8SFF**

![](https://www.dana-corp.com/wp-content/uploads/2024/06/Midplane-box-LFF.png)

| **شماره** | **توضیحات** |
| --- | --- |
| 1 | Box 7 |

**باکس های داخلی (****Midplane SFF****) سرور****DL380 Gen10 Plus 8SFF**

![](https://www.dana-corp.com/wp-content/uploads/2024/06/Midplane-box-SFF.png)

| **شماره** | **توضیحات** |
| --- | --- |
| 1 | Box 7 |

## **شماره گذاری درایو های انواع شاسی سرور**HPE DL380 Gen10 Plus

**هنگامی که درایو بک پلین مستقیماً به یک استوریج کنترلر متصل می شود، هر درایو باکس از شماره 1 شروع می شود. تصاویر زیر نمونه هایی از پیکربندی های رایج هستند.**

**24SFF**

![](https://www.dana-corp.com/wp-content/uploads/2024/06/24SFF.png)

**12SFF**

![](https://www.dana-corp.com/wp-content/uploads/2024/06/16SFF.png)

![](https://www.dana-corp.com/wp-content/uploads/2024/06/16SFF-.png)

**12LFF**

![](https://www.dana-corp.com/wp-content/uploads/2024/06/12LFF.png)

**6 SFF rear panel**

![](https://www.dana-corp.com/wp-content/uploads/2024/06/6SFF-Rear.png)

**2x 2 LFF rear panel**

![](https://www.dana-corp.com/wp-content/uploads/2024/06/4LFF-Rear.png)

**Universal media bay**

![](https://www.dana-corp.com/wp-content/uploads/2024/06/Universal-media-bay.png)

**8 LFF + Universal media bay, optional 2 SFF, and optical drive**

![](https://www.dana-corp.com/wp-content/uploads/2024/06/8-LFF-Universal-media-bay-optional-2-SFF.png)

**Midplane box LFF**

![](https://www.dana-corp.com/wp-content/uploads/2024/06/Midplane-LFF.png)

**Midplane box SFF**

![](https://www.dana-corp.com/wp-content/uploads/2024/06/Midplane-SFF.png)

## **معانی LED های هارد هایHPE Basic Drive**(BC)

**LFF low-profile drive carrier**

**درایو کدی (کریر) LFF LP یا  LFF low-profile درایوهای SAS و SATA را پشتیبانی می کند.**

![](https://www.dana-corp.com/wp-content/uploads/2024/06/LP-Caddy.png)

**SFF basic drive carrier**

درایو کدی (کریر) SFF BC یا  SFF basic carrier درایوهای SAS و SATA و NVMe را پشتیبانی می کند..

![](https://www.dana-corp.com/wp-content/uploads/2024/06/BC-SFF-Caddy.png)

| **Item** | **LED** | **Status** | **Definition** |
| --- | --- | --- | --- |
| 1 | Fault/Locate | Solid amber | This drive has failed, is unsupported, or is invalid. |
| Solid blue | The drive is operating normally and being identified by a management application. |  |  |
| Flashing amber/blue (1 flash per second) | The drive has failed, or a predictive failure alert has been received for this drive. The drive has also been identified by a management application. |  |  |
| Flashing amber (1 flash per second) | A predictive failure alert has been received for this drive. Replace the drive as soon as possible. |  |  |
| 2 | Online/Activity | Solid green | The drive is online and has no activity. |
| Flashing green (1 flash per second) | The drive is doing one of the following: Rebuilding or performing a RAIDPerforming a stripe size migrationPerforming a capacity expansionPerforming a logical drive extensionErasingSpare part activation |  |  |
| Flashing green (4 flashes per second) | The drive is operation normally and has activity. |  |  |
| Off | The drive is not configured by a RAID controller or is a spare drive. |  |  |

## **شماره گذاری فن ها** **سرور**HPE DL380 Gen10 Plus

![](https://www.dana-corp.com/wp-content/uploads/2024/06/FANs.png)

فلش به جلوی سرور اشاره می کند.

## **پورت ها وLED های کارتDSC-25 2-port SFP28**

**پورت ها**:

![](https://www.dana-corp.com/wp-content/uploads/2024/06/DSC-25-2-port.png)

| **Table 1. Ports** |  |  |
| --- | --- | --- |
| **شماره** | **پورت** | **توضیحات** |
| 1 | Management port | 1GbE RJ45 |
| 2 | Network interface port | 10/25G SFP+ based |
| 3 | Network interface port | 10/25G SFP+ based |
|   |   |   |

**LED ها**:

کارت  Pensando DSP DSC-25 2p SFP28 یک آداپتور شبکه SFP28 دو پورت، تک اسلات،  half-height, half-length (HHHL) است. دارای LED برای لینک (L) و Activity (A) برای هر پورت است. یک براکت half-height در تصویر زیر با پورت های SFP28 و LED ها نشان داده شده است.

![](https://www.dana-corp.com/wp-content/uploads/2024/06/DSC-25-2-LED.png)

| **Table 2. LED indicators** |  |  |  |
| --- | --- | --- | --- |
| **شماره** | **LED** | **Status** | **Description** |
| 1 | Management Port Activity LED | Off | No activity |
| Flashing | Passing traffic; flashing frequency indicates traffic intensity |  |  |
| 2 | Management Port Link LED | Off | A link has not been established |
| Solid green | Valid Ethernet link |  |  |
| 3 | SFP Port 1 Link/Activity LED | Off | A link has not been established |
| Solid green | Valid Ethernet link |  |  |
| Flashing green | Passing traffic; flashing frequency indicates traffic intensity |  |  |
| Solid amber | Link fault |  |  |
| 4 | SFP Port 2 Link/Activity LED | Off | A link has not been established |
| Solid green | Valid Ethernet link |  |  |
| Flashing green | Passing traffic; flashing frequency indicates traffic intensity |  |  |
| Solid amber | Link fault |  |  |
| 5 | System status LED | Off | System is not powered |
| Solid amber | Power is up, software has not booted yet |  |  |
| Solid green | System is up and fully operational |  |  |

**اجزای بوت دیوایس HPE NS204i-p NVMe**

![](https://www.dana-corp.com/wp-content/uploads/2024/06/NS204i-p.png)

| **شماره** | **توضیحات** |
| --- | --- |
| 1 | Drive bay 1 |
| 2 | Drive bay 2 |
| 3 | Thermal interface pad with removable liner |
| 4 | M.2 drive retaining latches |